Description Pulse Oximeter Finger Pulse Oximeter

Pulse Oximeter

Finger pulse oximeter

Description
The pulse oximeter, based entirely on digital technology, is; intended for non-invasive measurement of the control of functional oxygen saturation of arterial hemoglobin (SpO2). Pu Ò be used to measure human hemoglobin saturation and heart rate through the finger.
The product is; suitable for home use, hospital use (including clinical use in internal medicine / surgery, anesthesia, pediatrics, intensive care, etc.), medical and sports organizations and more.
Product features :
-Lightweight to carry and easy to use.
-Manual interface direction adjustment.
-LED color display, display for simultaneous reading of values and plethysmographic wave.
-Low perfusion up to 0.3%.
-Low battery indicator.
-Automatic shutdown.
-Two 1.5V AAA standard alkaline batteries support more; of 20 hours of continuous work.

Mode À of use
Instructions for the safe operation and use of the Pulse Oximeter :
-Do not open or attempt to repair the pulse oximeter so as not to compromise its correct functioning.
-Do not use the Pylsoximeter in situations where alarms are required. The device is not; equipped with alarms.
-The pulse oximeter shows a temporary measurement value each time, but cannot; be used for continuous monitoring.
-In subjects suffering from circulatory disturbances, prolonged use of the pulse oximeter can be painful. Do not use the pulse oximeter for longer; 2 hours per finger.
-Insert one of your fingers into the rubber hole of the pulse oximeter (make sure the finger is in the correct position, i.e. as far as it will go) with the nail surface facing up, then release the clamp.
- In order not to distort the measurement result, avoid using the pulse oximeter in the vicinity strong light sources (e.g. fluorescent lamps or direct sunlight).
-Reasons for possible interference:
1. Do not use the pulse oximeter in a magnetic resonance or axial tomography environment.
2. When measuring arm pressure with cuff.
3. Presence of arterial catheter or intravascular line, in patients with hypotension, severe vasoconstriction, with severe anemia or hypothermia, in the presence of cardiac arrest or in shock. 4. The presence of nail polish or false nails can cause inaccurate readings.
Setting parameters :
Press the power button (& gt ; 0.5 s), the oximeter will enter in the parameter setting. There are two submenus to choose: when the "*" signal is displayed in "Audio setting", press the button (> 0.5s) and enter the sound setting menu, repeatedly press the button, shifting the signal "*" to the item you want to select and press the button to set the desired value. Select "+" or "-" to increase or decrease the desired setting number. When the "*" signal is displayed on "Alm Setup", press the button (> 0.5s) and enter the alarms setup menu. Press the button to activate / deactivate the alarm and buzzer. When the "*" signal is displayed on the "Restore" item, press the button (> 0.5 s) and all settings return to the default settings.
Cleaning and disinfection :
Caution: Do not sterilize the high pressure pulse oximeter. Under no circumstances should the pulse oximeter be immersed in water, as moisture could infiltrate. and damage it.
Turn off the power and take out the batteries before cleaning the device. Keep the external surface of the device clean and free of dust and dirt. Clean the outer surface (including OLED screen) with a soft dry cloth. Use 75% medical alcohol to clean the surface and use a dry, low-alcohol fabric to prevent it from permeating into the device.
Warning:
-Do not use aggressive solvents. For example, acetone.
-Do not use abrasive material.
-Avoid any liquid coming into contact with the device and do not immerse any of the components of the device in any liquid.
-Avoid spilling liquids on the device during cleaning.
-Do not leave residues of detergents on the surface of the device.
Maintenance :
- Replace the batteries promptly when the display is; low battery indicator lit. Clean the surface of the pulse oximeter before using it in diagnosis for patients.
-Remove the batteries inside the battery compartment if the pulse oximeter fails. used for a long time.
- È better to store the product in a place where the ambient temperature is; between -10 and 40 ° C and humidity È between 10% - 80%.
-Inspect the device periodically to ensure that there is no obvious damage affecting its safety and performance.
-Do not use the product in the presence of flammable substances or at high temperatures and humidity above or below those recommended.

Troubleshooting :
Problem Possible cause Solutions
SpO2 or heart rate cannot be displayed normally 1. The finger is not; inserted correctly.
2. The patient's perfusion is; too low to measure
1. Try again by inserting your finger.
2. Try other times. Make sure there is no problem in the product, it is recommended to go to the hospital promptly for an exact diagnosis.
SpO2 and heart rate È displayed unstable 1. The finger may not be placed deep enough.
2. The finger is shaking or the patient's body is shaking; moving.
1. Try again by inserting your finger.
2. Try not to move, keep the patient calm.
The pulse oximeter does not turn on 1. The battery charge may be inadequate or not at all.
2. The batteries may not be inserted correctly.
3. The oximeter may be damaged.
1. Please replace the batteries.2. Please re-insert the batteries.
3. Please contact customer service.
The screen suddenly turns off 1. The product turns off automatically when no signal is detected for more than one. 8 seconds.
2. The quantity of battery energy È out of stock.
1. Normal.
2. Replace the batteries.

Warnings
Danger of explosion. Do not use the pulse oximeter near of flammable or explosive gas mixtures. Do not throw batteries into fire. Explosion risk. Do not attempt to recharge normal non-rechargeable batteries, liquid may leak and cause a fire or even explode. If the battery leaks, wear protective gloves and clean the battery compartment with a dry cloth. Keep the operating environment free from dust, vibrations, corrosive or flammable materials and temperatures and humidity; extreme. Do not use the unit if damp or wet due to condensation or splashing. Avoid using the equipment immediately after moving it from a cold environment to a warm and humid place. Do not use sharp or pointed objects to operate the front panel switches. If the device is not to be used for an extended period, remove the batteries from the battery compartment. The device should only be used if the battery cover is; Closed. Batteries must be disposed of properly according to local regulations after use.

Storage
Store at a temperature between -10 & deg; C and + 50 & deg; C.

Format
Dimensions: 60 mm (L) x 35 mm (W) x 32 mm (H).
Net weight: 50 g.