Description Pic Digy Personal Test Pregnancy 1 Piece
Pic Digy Personal Test Pregnancy
Device suitable for the early diagnosis of pregnancy, which allows to perform rapid tests based on the quantitative determination of human chorionic gonadotropin ('hCG') in 'urine. It is an in vitro diagnostic (IVD) device for self-diagnosis.The device allows you to detect concentrations equal to or greater than 25 mIU/ml in urine.
The specificity; it is been determined through reactivity studies. crusade with quantity; Notes of Luteinized Hormone (LH), Follicle Stimulating Hormone (FSH) and Thyroid Stimulating Hormone (TSH). Negative results were obtained in all tests conducted with 500 mIU/ml LH, 1,000 mIU/ml FSH, and 1,000 mcIU/ml TSH.
Mode – of use
Sample collection and preparation
To run the test, it is necessary to set up the test. It is possible to hold the absorbent part directly under the stream of urine, or to collect the urine in a special disposable container or other clean container for subsequent execution of the test. The kit can be used with any urine sample.
If it is not; If possible to test immediately, the sample should be stored at 4°C, and returned to room temperature before use.
To perform the test correctly, urine should not be stored for periods longer than 2 days.
Test procedure
Do not remove the device from the bag until the device is ready for use. you are not; ready to test.
Before carrying out the test, read the instructions carefully. The test must be performed at room temperature.
1. Remove a test device from the pouch by tearing it at the invitation. Grasping the handle with one hand, remove the cap with the other to reveal the absorbent tip.
Never hold the device with the absorbent tip facing upwards, for the entire duration of the procedure.
2. You can; choose whether to perform the test directly under the stream of urine or whether to use a urine sample previously collected in a container.
- Urine stream test:
Hold the absorbent tip pointing downwards under the urine stream.
Do not urinate on parts other than the absorbent tip. During sample collection, the device should be held at an angle greater than 45 degrees. The display will show the hourglass symbol. Within 10 seconds, you will hear the alarm. a beep and the hourglass symbol will start playing. to flash.
Remove the device from the stream of urine and keep the absorbent tip pointing downwards, or place the device horizontally on a flat surface.
If desired, it can be removed from the urine stream. possible to close the hood.
- Test with sample collected in a container:
Collect the urine in a clean and dry container. Completely immerse the absorbent tip in the urine.
Be careful not to get the test device wet. The display will show the hourglass symbol.
Within 10 seconds you will hear the hourglass. a beep and the hourglass symbol will start playing. to flash.
Remove the device from the urine and keep the absorbent tip pointing downwards, or place the device horizontally on a flat surface.
If desired, it can be removed from the urine. possible to close the hood.
3. The hourglass symbol will continue to run. flashing to indicate that the test is complete. in progress.
Within 5 minutes you will hear an alarm. a second beep and the hourglass symbol will stop playing. to flash.
Then it will appear; the result on the display.
Possible results are: Not Pregnant, Pregnant, and Error.
In the latter case, the test is not required. been done correctly, the result is correct. invalid or the device was used.
Then repeat the test with a new device.
If the hourglass symbol does not appear after using the test, consult the user manual.
Warnings
For in vitro diagnostic use only.
For external use only.
Do not ingest.
Dispose of after first use.
It cannot be be reused for running other tests.
Do not use the test kit after the expiration date.
Do not use the kit if the casing is damaged. punctured or not hermetically sealed.
Keep out of the reach of children.
Before performing the test, wash and dry your hands, which must remain clean and dry throughout the procedure.
Do not use the product outdoors.
To obtain precise results it is necessary to You must strictly follow the instructions.
The battery cannot be used. be replaced.
Follow local regulations when disposing of used test devices. Do not freeze.
As with any diagnostic procedure, confirmation of pregnancy can be done in the first place. only be performed by a physician following an evaluation of all required clinical and laboratory findings. The device is only suitable for use with human urine.
If the urine sample is too diluted, the quantity; of hCG contained in it may be insufficient.
If pregnancy is still suspected, collect another urine sample after at least 48 hours.
Then run the test again. A low hCG concentration in an early stage of pregnancy can lead to lead to a negative result.
In this case, repeat the test with a new urine sample after at least 48 hours. Medical procedures based on the use of hCG, such as fertility therapies, can lead to an erroneous result.
Consult your doctor.
Note that even using an unclean container or carrying out the procedure incorrectly could distort the result.