Glucomen Areo Sensor Glucose Analysis Strips 25 Pieces
Availability In stock
Discover the product
Description Glucomen Areo Sensor Glucose Analysis Strips 25 Pieces
Glucomen Areo Sensor Glucose Analysis Strips
in vitro diagnostic medical device.Sensors for the quantitative determination of the glucose level in the fresh capillary whole blood; they are to be used exclusively with the GlucoMen areo 2K instrument.
The sensors have been designed for monitoring and self-monitoring of blood glucose levels in people with diabetes mellitus; they can also be used in a hospital environment by medical personnel.
intended for use in the diagnosis or screening of diabetes, or use in infants.
Do not adjust your treatment based on test results without first consulting your doctor or healthcare professional.
General characteristics
Measuring blood glucose | specificity for beta-D-glucose in the blood |
Enzyme composition (per cm2) of a blood glucose test strip< /strong> | - glucose oxidase (from Aspergillus niger), 3.5% - mediator: hexacyanoferrate ion (III), 17, 5% - non-reactive substances, 79% |
Units; measurement | |
Glucose | mg/dL (not editable) |
Measuring range | |
Glucose | 20-600 mg /dL |
Response time | |
Glucose | 5 seconds |
Sample volume | |
0.5 microL | |
Acceptance range; hematocrit | |
Glucose | automatically corrects the measurement according to the hematocrit (10-70 %) |
Correlation | plasma equivalent |
fresh capillary whole blood | |
Sensors coding< /td> | autocoding |
Hygiene | automatic ejection of the test strip via dedicated eject button |
Sampling | automatic blood sample aspiration by capillarity; |
Use of alternative sites (AST) | allowed (palm and forearm) td> |
Operating environment | temperature range: 5-45°C humidity: 2 0%-90% (non-condensing) |
Mode of use
1. Insert a new GlucoMen areo Sensor (white) in the opening for inserting the sensors. The drop symbol will start flashing. flashing on the display and the glucose symbol 'Glu' will appear; lower left. If nothing appears on the display, remove the sensor, insert it back into the opening and wait for the drop symbol to start flashing.
For information on how to use the lancing device, read the corresponding instructions for use.< br/> 2. Hold the end of the of the sensor in contact with the drop of blood until the control visor is full. At that point, it will feel like it is. an acoustic signal (if enabled) and the display will show; a countdown.
3. Read the test results. An acoustic signal will announce the the test result will appear on the screen with the glucose symbol 'Glu'.
4. To remove the sensor, press the eject button. The instrument will turn off.
Warnings
Keep the instrument, sensors and other components out of the reach and sight of children. Small parts may present a choking hazard.
Handle the bottle and sensors with clean, dry hands.
Dispose of the bottle and used sensors in accordance with local regulations.
Handling blood can ; be dangerous: be extremely careful when handling the blood, the sensors, the lancets and the instrument.
Format
Pack of 25 sensors.