Description Gima Oxy-2 Finger Pulse Oximeter

Oximeter

The Finger Pulse Oximeter is a non-invasive device designed for instant saturation control arterial hemoglobin (SpO2) and heart rate of adults and children in home and hospital environments (including clinical use in internal/surgical therapy, anesthesia and intensive care, etc.).

  • It is not designed for continuous monitoring and is compact, practical to use and transport and with low energy consumption.
  • The two AAA batteries supplied can be used continuously for 24 hours. hours.
  • Automatic shutdown when no signal is received within 5 seconds and low battery indicator as a flashing battery icon.
  • The patient simply needs to insert their fingertip into the sensor photoelectric of the device and the Hemoglobin Saturation value appears immediately on the screen.

Features
Digital tube display with LED screen.
Interval SpO2 measurement range: 0%-100%;
Heart rate measurement range: 30 bpm - 250 bpm;
Heart rate intensity display: bar display;
Power requirement: 2 x 1.5 alkaline batteries V AAA; adaptive range: 2.6V - 3.6V;
Supply current: less than 25mA;
Resolution: 1% for SpO2 and 1bpm for heart rate;
Measurement accuracy: ±2 % in the 70%-100% SpO2 phase, and irrelevant when the phase is less than 70%. ±2 bpm or ±2% (select larger) for heart rate;
Measurement performance in the presence of low filling pressure: SpO2 and heart rate are displayed correctly when the heart rate-to-filling ratio is 0 ,4%. SpO2 error ±4%, heart rate error ±2 bpm or ±2% (select the larger);
It is equipped with function switch. The Pulse Oximeter turns off if it does not detect fingers in the device;
Optical sensor: red light (the wavelength is 660 nm, 6.65 mW) and infrared (the wavelength is 880 nm , 6.75 mW);

How to use
Insert the two batteries in the correct direction and then replace the cover.
Open the sensor and insert the patient's finger into the rubber-coated sensor (make sure the finger is in the correct position), then let the sensor close on the finger.
Press the power button on the front panel.
Do not move the finger and hold the patient at rest during the measurement.
The measurement results are shown directly on the display.

Storage methods
Store between -40°C and 60 °C. Relative humidity: ≤95%.